Testing Sensors on a Qolsys IQ Panel 5: PowerG Test, Legacy Sensor Test and What the Results Mean

A sensor that pairs is not the same as a sensor that works from where it is mounted. The IQ Panel 5 has two tests for that, one for PowerG devices and one for legacy 319, 345 and 433 MHz sensors on a daughter card, and both take a minute per device. Here is how to run them, read them, and what we do about a weak result.
- Strong is the target. Qolsys requires it for UL installs; we treat anything less as a placement question.
- Good means little margin: look for metal, mirrors or a detached building between sensor and panel.
- Poor or No Signal means move it or add a PowerG repeater. Check the battery and enrollment first.
- Legacy sensors have their own test under System Tests, and it is the one to run after every takeover or card swap.
- Once a year, every sensor, with the account on test at the monitoring center.
PowerG sensor test

The PowerG test under System Tests shows live signal strength for every PowerG sensor. Video by Qolsys.
- Settings → Advanced Settings → enter the installer or dealer code → System Tests → PowerG Test.
- Pick a sensor and let the panel ping it. The result is Strong, Good, Poor or No Signal, plus the average over the last 24 hours and, for a PIR camera, its last image.
- Repeat for every PowerG device. On a new install we do this before the covers go on for good.
Strong is the target. Qolsys requires Strong for UL-listed installs, and we treat Good as a reason to look at placement and Poor as a reason to move the sensor or add a PowerG repeater. PowerG has range to spare in a normal house; Poor usually means the sensor is inside a metal cabinet, behind a mirror, or in a detached garage.
Reading the result
| Result | What it means | What we do |
| Strong | Margin to spare; required for UL installs | Nothing |
| Good | Working, little margin | Check placement; move if inside metal or behind a mirror |
| Poor | Will drop off in bad conditions | Relocate, or add a PowerG repeater |
| No Signal | Not reaching the panel | Check battery and enrolment, then range |
Legacy (SRF) sensor test
The legacy-radio test under System Tests, for 319.5, 345 and 433 MHz sensors kept on a takeover. Video by Qolsys.
If the panel carries a legacy daughter card, the older sensors are tested under System Tests → Sensor Test. Trip each sensor and the panel graphs its signal against the ambient RF noise in the house. This is the test to run after a takeover, because the old sensors were placed for a different panel in a different location, and after a card swap, to prove the new card hears everything.
The rest of the test menu

While you are there: Daughter Cards Test confirms the legacy card itself, Panel Glass Break Test exercises the microphone, Dual Path Test checks that both Wi-Fi and cellular reach Alarm.com, and Z-Wave Tests sit next to the Z-Wave diagnostics. Glass break detectors have their own procedure, which we cover in a separate post.
The annual test, in order
- Put the account on test. One call to the monitoring center, or to us, so the walk test does not dispatch anyone.
- PowerG test on every device, reading the 24-hour average as well as the live ping.
- Walk test every door, window and motion and watch the panel log each one.
- Legacy sensor test if a daughter card is fitted, then the Daughter Cards test itself.
- Dual Path test, so both Wi-Fi and cellular are proven to reach Alarm.com, then a battery check and a note in the account.
Frequently asked
How often should sensors be tested? Annually at minimum, and after any change: a takeover, a card swap, a remodel that moved walls or added a metal backsplash.
A sensor reads Good. Is that a problem? Not today. It is a sensor with little margin, so a new appliance or a mirror on the wall can push it to Poor. We note it and check placement.
What is a PowerG repeater? A plug-in device that relays PowerG signals. One repeater usually fixes a detached garage, shop or a sensor inside a metal cabinet.
Can I run these tests myself? The menu needs the installer or dealer code. Homeowners can watch the sensor list and history, which is enough to confirm a door is reporting.
Does the panel test the glass breaks? The Panel Glass Break Test exercises the panel’s own microphone. Standalone detectors have a separate procedure in our glass break guide.
Our annual routine. Every monitoring customer gets a full sensor test once a year: PowerG test on every device, a walk test of every door, window and motion with the system in test at the monitoring center, and a battery check. It takes about an hour and it is the visit that catches the sensor that quietly stopped reporting in March.
Shield Low Voltage installs and services Qolsys IQ Panel systems with Alarm.com monitoring across Utah County, Salt Lake County and the Wasatch Back. Related: installing the legacy daughter card and why your panel is beeping. Videos and images courtesy of Qolsys, a Johnson Controls company.