Replacing Batteries on a Qolsys IQ Panel 5 System: Panel, Sensors, Detectors and the IQ Lock

When an IQ Panel 5 says Low Battery, it tells you which device. PowerG batteries last years, which is exactly why nobody remembers how to change them. Here is every battery in a typical system, with Qolsys’s clip for each, the three rules that prevent a false alarm or a dead sensor, and the one procedure that can damage the panel if you skip it.
- Disarm the system. Opening a sensor cover trips its tamper. Disarmed, that is a chime and a message; armed, it can be an alarm and a phone call from monitoring.
- Put the account on test for life-safety devices. Smoke and heat detectors are armed 24 hours a day. Call the monitoring center, or us, before you open one.
- Use the printed battery type. It is on a label inside every cover. Most PowerG+ sensors take CR123A or CR2 lithium cells; do not substitute alkaline in a sensor. The IQ Lock-PG is the exception: it runs on AA alkalines.
Every battery in the system
| Device | Typical cells | How it opens | Expected life |
| IQ Panel 5 | Internal lithium pack (Qolsys part) | Menu power-down, back off, 6-pin connector | 3 to 5 years |
| Door/window contact | Lithium, CR123A or CR2 (see label) | Slide the cover | Up to 6 years |
| Motion detector | Lithium CR123A (see label) | Pry at the base notch | Up to 6 years |
| PIR camera | Multiple lithium cells (see label) | Pry at the base notch | 2 to 4 years |
| Glass break | Lithium CR123A (see label) | Single screw, lift cover | Up to 6 years |
| Smoke / heat detector | Lithium cells (see label) | Twist off the base | Up to 6 years |
| IQ Lock-PG | AA alkaline, 4 | Interior cover | About 1 year |
Cell types are printed inside each cover and in the device manual; when in doubt, read the label rather than this table.
The panel battery

Menu power-down first, then the 6-pin connector, then the pack. Video by Qolsys.
- Power the panel down from the menu. Settings → Advanced Settings → enter the installer or dealer code → Power Down. Wait for the LED to go dark, then unplug the power supply. Qolsys is blunt about this: pulling power first can corrupt the panel.
- Open the back. Loosen the locking screw on the bottom edge and lift the panel off its backplate or stand.
- Unplug the 6-pin battery connector from the board, lift the battery out of its plastic hold-down by the edge, never with a screwdriver.
- Fit the new pack, route the cable between the battery and the daughter cards, plug the connector back in.
- Close up, reconnect power, hold the power button three seconds. Connect the battery before the power supply or the panel reads the battery wrong.
Door and window contacts

Slide the cover, swap the CR123A, close it and the panel clears the low-battery message. Video by Qolsys.
Slide or pry the cover as the clip shows, note the orientation of the old cell, fit the new one, close the cover firmly. The tamper clears when the cover seats, and the low-battery message clears on the sensor’s next check-in, which can take a few minutes. Open and close the door once to confirm the panel sees it.
Indoor motion detectors

Open the case, swap the batteries, close it so the tamper clears. Video by Qolsys.
After closing the cover, give the detector a minute to settle, then walk the room and watch for the LED or the panel’s sensor status to show activity. If it does not, the cover is not fully seated.
Indoor PIR camera

The PIR camera takes the same batteries as the motion, behind the same cover. Video by Qolsys.
The camera version uses more cells than a plain motion. Replace all of them together; mixing old and new is the most common reason a PIR camera reports low battery again a month later.
Glass break detectors

Closing the cover starts a 15-minute test mode, so finish the swap before you test. Video by Qolsys.
Closing the cover puts the detector into its 15-minute test mode, which is a good moment to do the flex test in our glass break testing guide.
Smoke, heat and smoke/heat detectors

Twist the detector off its base before opening it, so the swap does not trip a fire alarm. Video by Qolsys.
Put the account on test before you start. Twist the detector off its base, replace the cells as marked, twist it back on until it clicks, and press the test button once to confirm it sounds and the panel registers it. Do not paint around them, and replace the whole detector at the age printed on the back, usually ten years.
IQ Lock-PG

Interior cover off, battery pack out, new cells in. Once a year. Video by Qolsys.
Remove the interior cover, lift out the battery holder, fit fresh cells, and run the lock once from the panel to confirm. We change lock batteries on every annual visit whether they are low or not.
Frequently asked
Can I use alkaline batteries? Not in the sensors. PowerG sensors are specified for lithium cells, CR123A or CR2 as printed inside the cover. Alkaline voltage sags and the sensor reports low again within weeks. The one device in the system that does take alkalines is the IQ Lock-PG, which uses four AAs.
Why did the panel alarm when I opened a sensor? The cover tamper. Disarm first; for smoke and heat detectors, put the account on test as well because they are armed 24 hours a day.
How long do the batteries last? Years, not months. Contacts and motions commonly reach five or six years; the panel pack three to five; PIR cameras less because they send images.
The low-battery message will not clear. What now? Wait ten minutes for the next check-in. If it persists, re-seat the cover, check cell orientation, or open and close the cover once to force a tamper and restore.
Can you do all of this on one visit? Yes. The annual visit for our monitoring customers includes every battery in the system, replaced whether or not it is low.
Message will not clear? Give it ten minutes. If it persists, the cover is not seated, the cells are in backwards, or the battery was dead long enough that the panel wants a tamper and restore: open the cover, wait five seconds, close it again.
Shield Low Voltage installs and services Qolsys IQ Panel systems with Alarm.com monitoring across Utah County, Salt Lake County and the Wasatch Back. Related: installing the legacy daughter card and why your panel is beeping. Videos and images courtesy of Qolsys, a Johnson Controls company.